추천 제품
Quality Level
주관자
Merck & Co., Inc., Kenilworth, NJ, U.S.
SMILES string
O[C@H]([C@@H](O)C(O)=O)C(O)=O.C[C@H](N)[C@H](O)c1cccc(O)c1
InChI
1S/C9H13NO2.C4H6O6/c1-6(10)9(12)7-3-2-4-8(11)5-7;5-1(3(7)8)2(6)4(9)10/h2-6,9,11-12H,10H2,1H3;1-2,5-6H,(H,7,8)(H,9,10)/t6-,9-;1-,2-/m01/s1
InChI key
VENXSELNXQXCNT-IJYXXVHRSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
관련 카테고리
애플리케이션
Metaraminol (+)-bitartrate salt has been used to study the effects of adrenergic agonists in the mouse model of endometriosis.
생화학적/생리학적 작용
α-adrenoceptor agonist.
Metaraminol may serve as a false sympathetic transmitter. It is a mixed α - and β-adrenergic agonist.
Metaraminol may serve as a false sympathetic transmitter. It is a mixed α - and β-adrenergic agonist.
특징 및 장점
This compound was developed by Merck & Co., Inc., Kenilworth, NJ, U.S.. To browse the list of other pharma-developed compounds and Approved Drugs/Drug Candidates, click here.
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral
Storage Class Code
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
WGK
WGK 3
개인 보호 장비
Eyeshields, Faceshields, Gloves, type P2 (EN 143) respirator cartridges
Studies on the interrelationship between the syntheses of noradrenaline and metaraminol
Johnson GE and Pugsley TA
British Journal of Pharmacology, 39(1), 167-174 (1970)
J Tanaka et al.
Experimental neurology, 152(2), 303-306 (1998-08-26)
To verify whether noradrenergic inputs to the subfornical organ (SFO) are involved in the control system of arterial pressure, we investigated the effects of blood pressure changes on noradrealine (NA) release in the SFO and its surrounding sites using microdialysis
Einly Lim et al.
Artificial organs, 36(5), E110-E124 (2012-04-12)
A heart-pump interaction model has been developed based on animal experimental measurements obtained with a rotary blood pump in situ. Five canine experiments were performed to investigate the interaction between the cardiovascular system and the implantable rotary blood pump over
Impact of admixture time and diluent order on metaraminol concentration.
J N Darvall et al.
Anaesthesia and intensive care, 37(5), 859-860 (2009-09-25)
Marilyn P Law et al.
Journal of nuclear medicine : official publication, Society of Nuclear Medicine, 51(8), 1269-1276 (2010-08-04)
Dysfunction of the sympathetic nervous system underlies many cardiac diseases and can be assessed by molecular imaging using PET in humans. Small-animal PET should enable noninvasive quantitation of the sympathetic nervous system in mouse models of human disease. For mice
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.