추천 제품
특징
wetted part: no
제조업체/상표
Cytiva 80-6484-51
포장
pkg of 50 samples
관련 카테고리
일반 설명
2-D Clean-Up Kit is designed to prepare samples for 2-D electrophoresis that otherwise produce poor 2-D spot-maps due to high conductivity, high levels of interfering substances, or low protein concentration. The reagents quantitatively precipitate proteins while leaving interfering substances, such as detergents, salts, lipids, phenolics, and nucleic acids, in solution.
Treatment of the sample with 2-D Clean-Up Kit can improve the quality of 2-D electrophoresis results, reducing streaking, background staining, and other artifacts due to interfering contaminants. The kit can make 2-D analysis possible for samples that are otherwise too dirty or too dilute.
The 2-D Clean-Up Kit procedure uses precipitant and co-precipitant in combination to quantitatively precipitate proteins. Precipitated proteins are pelleted by centrifugation and the precipitate is further washed to remove nonprotein contaminants. After a second centrifugation, the resultant pellet is resuspended into denaturing sample solution for first-dimension IEF.
The procedure can be completed in 90 min and does not result in spot gain or loss. The kit contains sufficient reagents to process 50 samples of up to 100 μ each. The procedure can be scaled up for larger volumes or more dilute samples.
2-D Clean-Up Kit increases labeling efficiency and protein abundance when using 2-D Fluorescence Difference Gel Electrophoresis (2-D DIGE).
Treatment of the sample with 2-D Clean-Up Kit can improve the quality of 2-D electrophoresis results, reducing streaking, background staining, and other artifacts due to interfering contaminants. The kit can make 2-D analysis possible for samples that are otherwise too dirty or too dilute.
The 2-D Clean-Up Kit procedure uses precipitant and co-precipitant in combination to quantitatively precipitate proteins. Precipitated proteins are pelleted by centrifugation and the precipitate is further washed to remove nonprotein contaminants. After a second centrifugation, the resultant pellet is resuspended into denaturing sample solution for first-dimension IEF.
The procedure can be completed in 90 min and does not result in spot gain or loss. The kit contains sufficient reagents to process 50 samples of up to 100 μ each. The procedure can be scaled up for larger volumes or more dilute samples.
2-D Clean-Up Kit increases labeling efficiency and protein abundance when using 2-D Fluorescence Difference Gel Electrophoresis (2-D DIGE).
애플리케이션
Automated identification and quantitation of proteins and peptides using LC-MS/MS.
특징 및 장점
- Improves the quality of 2-D electrophoresis results by removing interfering contaminants
- Quantitative precipitation separates proteins from detergents, salts, lipids, phenolics and nucleic acids
- Delivers quantitative yield in about 90 min.
저장 및 안정성
Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
The wash buffer should be placed at -20 °C at least 1 h before use and may be s-red in a -20 °C freezer
분석 메모
To view the Certificate of Analysis for this product, please visit www.cytiva.com.
신호어
Danger
유해 및 위험 성명서
Storage Class Code
8B - Non-combustible corrosive hazardous materials
가장 최신 버전 중 하나를 선택하세요:
프로토콜
Mini Dialysis Kit from GE Healthcare Lifescience is designed for the dialysis of small sample volumes with minimal handling and sample loss and reduces the pronounced streaking on 2-D gels caused by low-molecular-weight contaminants.
Sample Grinding Kit from GE Healthcare is designed to disrupt cell or tissue samples for protein extraction.
2-D Clean-Up Kit from GE Healthcare is designed to prepare samples that would otherwise produce poor 2-D results.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.