추천 제품
Grade
analytical standard
Quality Level
유통기한
limited shelf life, expiry date on the label
응용 분야
clinical testing
형식
neat
SMILES string
C[N+](C)(CCCCCCCCCC)CCCCCCCCCC.[Cl-]
InChI
1S/C22H48N.ClH/c1-5-7-9-11-13-15-17-19-21-23(3,4)22-20-18-16-14-12-10-8-6-2;/h5-22H2,1-4H3;1H/q+1;/p-1
InChI key
RUPBZQFQVRMKDG-UHFFFAOYSA-M
유사한 제품을 찾으십니까? 방문 제품 비교 안내
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 4 Oral - Aquatic Chronic 1 - Eye Dam. 1 - Skin Corr. 1B
Storage Class Code
8A - Combustible corrosive hazardous materials
WGK
WGK 2
이미 열람한 고객
Alice Roedel et al.
Microorganisms, 8(4) (2020-04-16)
We investigated the suitability of a newly developed biocide susceptibility test system based on microtiter plates containing vacuum dried biocides as a fast and reliable screening method. The evaluated substances included the cationic biocides benzalkonium chloride (BAC), chlorhexidine dihydrochloride (CHX)
Anyun Zhang et al.
Microbial drug resistance (Larchmont, N.Y.), 22(1), 80-87 (2015-07-15)
To demonstrate the resistance of antibiotics and disinfectants to Escherichia coli isolates, 255 E. coli strains were isolated from 328 retail meat samples in this study. Susceptibility testing results showed that 85.5% isolates were resistant to at least one antibiotic
H Uzuner et al.
The Journal of hospital infection, 100(3), e30-e36 (2018-05-25)
Hand antiseptics are of great importance in the prevention of nosocomial infections. Due to the frequent occurrence of adenoviral epidemic keratoconjunctivitis outbreaks in the study hospital, it was necessary to investigate the efficiency of alcohol-based solutions on adenoviruses. To investigate
Robin S Wegh et al.
Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment, 34(11), 1935-1947 (2017-08-08)
A non-targeted workflow is reported for the isolation and identification of antimicrobial active compounds using bioassay-directed screening and LC coupled to high-resolution MS. Suspect samples are extracted using a generic protocol and fractionated using two different LC conditions (A and
Çiğdem Arpa et al.
Journal of analytical methods in chemistry, 2018, 8951028-8951028 (2018-08-30)
Ultrasound-assisted dispersive liquid-liquid microextraction method based on solidification of floating organic drop and back-extraction (UA-DLLME-SFO-BE) technique was proposed for preconcentration of lead ions. In this technique, two SFODME steps are applied in sequence. The classical SFODME was applied as the
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.