About This Item

실험식(Hill 표기법):
C38H55N3O
CAS Number:
Molecular Weight:
569.86
Beilstein:
5462368
MDL number:
UNSPSC 코드:
26111700
PubChem Substance ID:
NACRES:
NB.61

제품 라인

Selectophore

Quality Level

양식

solid

SMILES string

CCCCCCCCC(CCCCCCCC)C\N=C1/C=C2Oc3cc(ccc3N=C2c4ccccc14)N(CC)CC

InChI

1S/C38H55N3O/c1-5-9-11-13-15-17-21-30(22-18-16-14-12-10-6-2)29-39-35-28-37-38(33-24-20-19-23-32(33)35)40-34-26-25-31(27-36(34)42-37)41(7-3)8-4/h19-20,23-28,30H,5-18,21-22,29H2,1-4H3/b39-35+

InChI key

ICVAQSQRYBGWQH-IGIMMJHKSA-N

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

Chromoionophore III (ETH 5350) is a pH sensitive dye, and is ratiometric that is the fluorescence spectrum has two peaks, and the ratio between these peaks changes according to the changing pH levels.
Visit our Sensor Applications portal to learn more.

애플리케이션

Selected application examples
Assay of Na+ activity with solvent polymeric optode membrane prepared from ETH 5350 and sodium ionophore V; Assay of ammonia with solvent polymeric optode membranes based on ETH 5350 and valinomycin (potassium ionophore I)
ETH 5350 was used for the fabrication of optode membranes, which are sodium selective, used in order to optically determine sodium in pH-buffered human blood plasma.

포장

Bottomless glass bottle. Contents are inside inserted fused cone.

법적 정보

Selectophore is a trademark of Merck KGaA, Darmstadt, Germany

Storage Class Code

11 - Combustible Solids

WGK

WGK 3

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable

개인 보호 장비

Eyeshields, Gloves, type N95 (US)


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 문서 section.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Magnetic microdrill as a modulated fluorescent pH sensor.
McNaughton
Journal of magnetism and magnetic materials, 293 (1), 696-701 (2005)
A A Galyean et al.
The Analyst, 143(2), 458-465 (2017-12-12)
Nanosensors present a biological monitoring method that is biocompatible, reversible, and nano-scale, and they offer many advantages over traditional organic indicators. Typical ionophore-based nanosensors incorporate nile-blue derivative pH indicators but suffer from photobleaching while quantum dot alternatives pose a potential
Characterization of sodium-selective optode membranes based on neutral ionophores and assay of sodium in plasma.
Seiler K
Clinical Chemistry, 37 (8), 1350-1355 (1991)

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..