1.08110
Tetrahydrofuran
≥99.9% (GC), suitable for UV/Vis spectroscopy, Uvasol®
Synonym(s):
THF, Tetramethylene oxide, Oxolane, Butylene oxide, Butylene oxide, Oxolane, Tetramethylene oxide
About This Item
143 mmHg ( 20 °C)
Product Name
Tetrahydrofuran, for spectroscopy Uvasol®
vapor density
2.5 (vs air)
Quality Level
vapor pressure
114 mmHg ( 15 °C)
143 mmHg ( 20 °C)
Assay
≥99.9% (GC)
form
liquid
autoignition temp.
610 °F
expl. lim.
1.8-11.8 %
technique(s)
UV/Vis spectroscopy: suitable
impurities
≤0.0002 meq/g Acidity
≤0.0002 meq/g Alkalinity
≤0.01% Water
evapn. residue
≤0.0002%
color
APHA: ≤10
transmittance
215 nm, ≥30%
245 nm, ≥50%
265 nm, ≥80%
275 nm, ≥90%
310 nm, ≥98%
refractive index
n20/D 1.407 (lit.)
pH
7-8 (20 °C, 200 g/L in H2O)
bp
65-67 °C (lit.)
mp
−108 °C (lit.)
transition temp
flash point -20 °C
density
0.889 g/mL at 25 °C (lit.)
UV absorption
λ: 215 nm Amax: ≤0.52
λ: 245 nm Amax: ≤0.30
λ: 265 nm Amax: ≤0.10
λ: 275 nm Amax: ≤0.05
λ: 310 nm Amax: ≤0.01
storage temp.
2-30°C
SMILES string
C1CCOC1
InChI
1S/C4H8O/c1-2-4-5-3-1/h1-4H2
InChI key
WYURNTSHIVDZCO-UHFFFAOYSA-N
Analysis Note
Evaporation residue: ≤ 0.0002 %
Water: ≤ 0.01 %
Colour: ≤ 10 Hazen
Acidity: ≤ 0.0002 meq/g
Alkalinity: ≤ 0.0002 meq/g
Fluorescence (as quinine at 254 nm): ≤ 1.0 ppb
Fluorescence (as quinine at 365 nm): ≤ 1.0 ppb
Transmission (at 215 nm): ≥ 30 %
Transmission (at 245 nm): ≥ 50 %
Transmission (at 265 nm): ≥ 80 %
Transmission (at 275 nm): ≥ 90 %
Transmission (from 310 nm): ≥ 98 %
Absorbance (at 215 nm): ≤ 0.52
Absorbance (at 245 nm): ≤ 0.30
Absorbance (at 265 nm): ≤ 0.10
Absorbance (at 275 nm): ≤ 0.05
Absorbance (from 310 nm): ≤ 0.01
Other Notes
Legal Information
Still not finding the right product?
Explore all of our products under Tetrahydrofuran
Signal Word
Danger
Hazard Statements
Precautionary Statements
Hazard Classifications
Acute Tox. 4 Oral - Carc. 2 - Eye Irrit. 2 - Flam. Liq. 2
Supplementary Hazards
Storage Class Code
3 - Flammable liquids
WGK
WGK 1
Flash Point(F)
-6.2 °F - closed cup
Flash Point(C)
-21.2 °C - closed cup
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.