추천 제품
제품 라인
ProteoMass™
Quality Level
CofA
current certificate can be downloaded
포장
pkg of 1 × 10 mL
저장 조건
protect from light
농도
(varied conc.)
기술
mass spectrometry (MS): suitable
형식
multi-component solution
배송 상태
dry ice
저장 온도
−20°C
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
The ProteoMass ESI Calibration Kit for LTQ based Hybrids, positive ion mode calibration solution, enables calibration of Thermo Scientific hybrid instruments equipped with ESI source in positive ion mode. It covers a mass range from m/z 138 to m/z 1822, and is therefore usable for calibrations between m/z 50 and 2000.
애플리케이션
ProteoMass™ LTQ/FT-hybrid ESI Pos. mode cal mix has been used as a calibration standard for the mass spectrometric analysis of serum samples of patients affected by mugwort pollen allergy induced by pollen extract of Artemisia vulgaris.
특징 및 장점
Discover the Advantages for Yourself!
- Ready-to-use
- Developed and qualified specifically for use with the LTQ based Thermo Scientific hybrid instruments (LTQ FT, LTQ FT Ultra, and LTQ Orbitrap series) with ESI source and Thermo Scientific Exactive
- Conveniently packaged, freeing you from time consuming mixing and dilution steps, allowing you to focus on the acquistion of quality data
법적 정보
ProteoMass is a trademark of Sigma-Aldrich Co. LLC
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Eye Irrit. 2 - Flam. Liq. 2 - STOT SE 1
표적 기관
Eyes,Central nervous system
Storage Class Code
3 - Flammable liquids
WGK
WGK 2
Flash Point (°F)
42.1 °F - closed cup
Flash Point (°C)
5.6 °C - closed cup
가장 최신 버전 중 하나를 선택하세요:
이미 열람한 고객
D Apostolovic et al.
Scientific reports, 7(1), 5201-5201 (2017-07-14)
The mammalian carbohydrate galactose-α1,3-galactose (α-Gal) causes a novel form of food allergy, red meat allergy, where patients experience severe allergic reactions several hours after red meat consumption. Here we explored gastric digestion of α-Gal glycoproteins using an in vitro model.
High-resolution mass spectrometry analysis of secondary organic aerosol generated by ozonolysis of isoprene.
Nguyen, T.B., et al.
Atmospheric Environment, 44(8), 1032-1042 (2010)
H Gallart-Ayala et al.
Rapid communications in mass spectrometry : RCM, 25(20), 3161-3166 (2011-09-29)
Benzophenone (BP) is one of the many contaminants reported as present in foodstuffs due to its migration from food packaging materials. Liquid chromatography/tandem mass spectrometry (LC/MS/MS) is acknowledged in the literature as the method of choice for this analysis. However
Towards data acquisition throughput increase in Fourier transform mass spectrometry of proteins using double frequency measurements.
Vorobyev, A., et al.
International Journal of Mass Spectrometry and Ion Processes, 306(2-3), 227-231 (2011)
Jérôme Laparre et al.
Analytica chimica acta, 951, 99-107 (2016-12-22)
Urine stability during storage is essential in metabolomics to avoid misleading conclusions or erroneous interpretations. Facing the lack of comprehensive studies on urine metabolome stability, the present work performed a follow-up of potential modifications in urinary chemical profile using LC-HRMS
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.