추천 제품
제품 라인
BioReagent
Quality Level
분석
≥95% (HPLC)
양식
powder
solubility
methanol: soluble
형광
λex 486 nm; λem ~600 nm in 0.1 M sodium borate pH 9.0 (after derivatization with glycine)
적합성
suitable for fluorescence
저장 온도
2-8°C
SMILES string
[H]C(=O)c1nc2ccccc2cc1C(=O)c3ccco3
InChI
1S/C15H9NO3/c17-9-13-11(15(18)14-6-3-7-19-14)8-10-4-1-2-5-12(10)16-13/h1-9H
InChI key
PNCHURHVMDRFTR-UHFFFAOYSA-N
일반 설명
3-(2-Furoyl)quinoline-2-carboxaldehyde is a neutral fluorogenic probe for amines for the picomolar assay of proteins by capillary electrophoresis (CE).
신호어
Warning
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 4 Oral - Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
표적 기관
Respiratory system
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
dust mask type N95 (US), Eyeshields, Gloves
Tingting Zhao et al.
Electrophoresis, 42(4), 350-359 (2020-11-29)
A quantitative method was developed for the direct identity confirmation and quantification of alendronate using CE-MS combined with a pH-assisted focusing technique, dynamic pH barrage junction focusing. A pH-induced variation in electrophoretic mobility led to online focusing of alendronate at
Alexander V Stoyanov et al.
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 780(2), 283-287 (2002-10-29)
Fluorogenic reagents are used for protein labeling when high-sensitivity fluorescence detection is required. Similar to traditional labeling with activated fluorescent dyes, such as fluorescein isothiocyanate, a fluorogenic reaction is expected to change the physical-chemical properties of proteins. Knowledge of these
Juan Feng et al.
Electrophoresis, 29(2), 475-482 (2007-12-08)
Carbonyl-modified proteins are markers of oxidative damage. Here, we report a new method for detecting and quantifying carbonylated proteins by capillary sieving electrophoresis (CSE) with LIF detection (CSE-LIF). Alexa 488 hydrazide is used for the specific labeling of carbonyls while
David A Michels et al.
Analytical chemistry, 79(15), 5963-5971 (2007-06-27)
A fast and improved sample preparation scheme was developed for protein analysis using capillary electrophoresis-sodium dodecyl sulfate (CE-SDS) with laser-induced fluorescence detection. This CE-SDS method was developed as a purity assay for recombinant monoclonal antibodies (rMAbs). In this assay, rMAbs
Melissa M Harwood et al.
Electrophoresis, 28(6), 932-937 (2007-02-20)
The composition of single MCF-7 breast cancer cells is characterized using 2-D CE. Individual MCF-7 cells were aspirated into a 30 mum inner diameter fused-silica capillary and lysed by contact with an SDS-containing buffer. Proteins and other primary amines were
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.