추천 제품
Quality Level
양식
chunks
기술
gas chromatography (GC): suitable
입자 크기
6 mesh
SMILES string
[Ca++].[O-]S([O-])(=O)=O
InChI
1S/Ca.H2O4S/c;1-5(2,3)4/h;(H2,1,2,3,4)/q+2;/p-2
InChI key
OSGAYBCDTDRGGQ-UHFFFAOYSA-L
유사한 제품을 찾으십니까? 방문 제품 비교 안내
관련 카테고리
일반 설명
Drierite™ (CaSO4) is widely employed as a chemical desiccant in laboratories. Its use is preferred over silica gel for the estimation of CO2. It acts as a drying agent by absorbing moisture in air to form CaSO4 hemihydrate.
애플리케이션
Drierite™ (CaSO4) was used in Drierite™/Ascarite column for the purification of air during the estimation of CO2 production by flow-through respirometry system.
it may be employed as drying agent in the following studies:
it may be employed as drying agent in the following studies:
- For the removal of water via adsorption during the gas-chromatographic estimation of methanol, ethanol and isopropanol in biological samples.
- As scrubber for the drying of air.
- For the drying of nitrile samples during the calorimetric estimation of their enthalpies of vaporization.
- For the removal of water vapor during the coulometric estimation of carbon dioxide for air pollution monitoring.
법적 정보
Drierite is a trademark of W.A. Hammond Drierite Co., LTD
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Aquatic Chronic 2 - Carc. 1B - Repr. 1B
Storage Class Code
6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
이미 열람한 고객
Cold-induced expression of diapause in Praon volucre: fitness cost and morpho-physiological characterization.
Colinet H, et al.
Physiological Entomology, 35(4), 301-307 (2010)
The ontogeny of personality in the wild guinea pig.
Guenther A, et al.
Animal behaviour, 90, 131-139 (2014)
The analysis of carbon monoxide in urban air at the ppm level, and the normal carbon monoxide value.
L Dubois et al.
Journal of the Air Pollution Control Association, 16(3), 135-139 (1966-03-01)
Respirometry: anhydrous drierite equilibrates with carbon dioxide and increases washout times.
White CR, et al.
Physiological and Biochemical Zoology : Pbz, 79(5), 977-988 (2006)
GAS CHROMATOGRAPHIC DETERMINATION OF LOWER ALCOHOLS IN BIOLOGIC SAMPLES.
H LYONS et al.
Clinical chemistry, 10, 429-432 (1964-05-01)
프로토콜
US EPA Method 8270 (Appendix IX): GC Analysis of Semivolatiles on Equity®-5 (30 m x 0.25 mm I.D., 0.50 μm)
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.