919233

Sigma-Aldrich

Sodium 2-(4-hexylphenyl)diazene-1-sulfonate

(0.5% solution in 25mM aqueous ammonium bicarbonate, pH 7.0), ≥95%

동의어(들):

4-Hexylphenylazosulfonate, Azo

로그인조직 및 계약 가격 보기


About This Item

실험식(Hill 표기법):
C12H17N2O3S · Na
CAS Number:
Molecular Weight:
292.33
MDL number:
UNSPSC 코드:
12161503
NACRES:
NA.22

Quality Level

분석

≥95%

양식

liquid

refractive index

n/D 1.334

density

0.994 g/mL

저장 온도

2-8°C

SMILES string

[Na+].[S](=O)(=O)(\N=N\c1ccc(cc1)CCCCCC)[O-]

InChI

1S/C12H18N2O3S.Na/c1-2-3-4-5-6-11-7-9-12(10-8-11)13-14-18(15,16)17;/h7-10H,2-6H2,1H3,(H,15,16,17);/q;+1/p-1/b14-13+;

InChI key

GOFLQKOPOSFUCU-IERUDJENSA-M

애플리케이션

4-Hexylphenylazosulfonate (Azo) is a photocleavable anionic surfactant developed by the Ge lab for use in high-throughput top-down and bottom-up proteomics by mass spectrometry (MS). Initially, the reagent showed a breakthrough as an improved method for top-down analysis [Brown et al. 2019]. Top-down analysis looks at intact proteins, while bottom-up analysis uses digested proteins. Of the two, top-down analysis is preferable for detecting post-translational modifications and sequence variations. Bottom-up is more commonly used and is likely to detect more proteins. This reagent was also shown to work for sample extraction that can be used for both top-down and bottom-up analysis on the same sample to maximize data collection[Brown et al. 2020].

Surfactants are required for protein extraction especially for challenging classes of protein including membrane proteins[Brown et al. 2020] and extracellular matrix proteins[Knott et al. 2020], but surfactants suppress the signal in MS. While removing a surfactant will improve the signal, this can cause protein loss and degradation. Azo allows for easy removal since it can be rapidly degraded using ultraviolet irradiation (λmax = 305 nm). Using Azo in this way reduces protein loss and gives an improved signal. Please see the Ge lab publications for information on using this product [Brown et al. 2019, Brown et al. 2020, Knott et al. 2020, and Aballo et al. 2021].

Product can be used with our line of photoreactors: Including Penn PhD (Z744035) & SynLED 2.0 (Z744080)

법적 정보

PCT/US2019/035447

Storage Class Code

10 - Combustible liquids

WGK

WGK 2


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 문서 section.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Photocleavable Surfactant-Enabled Extracellular Matrix Proteomics.
Knott S J, et al.
Analytical Chemistry, 92(24), 15693-15698 (2020)
Kyle A Brown et al.
Nature methods, 16(5), 417-420 (2019-04-17)
We report the identification of a photocleavable anionic surfactant, 4-hexylphenylazosulfonate (Azo), which can be rapidly degraded by ultraviolet irradiation, for top-down proteomics. Azo can effectively solubilize proteins with performance comparable to that of sodium dodecyl sulfate (SDS) and is compatible

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.