1.04873
Potassium phosphate monobasic
for analysis EMSURE® ISO
동의어(들):
Potassium phosphate monobasic, Potassium dihydrogen phosphate, mono-Potassium orthophosphate, Potassium biphosphate, Potassium phosphate monobasic, Monopotassium phosphate, prim.-Potassium phosphate
About This Item
추천 제품
Agency
reag. ISO
suitable for SM 5210
Quality Level
제품 라인
EMSURE®
분석
≥99.5% dry basis (alkalimetric)
99.5-100.5% (alkalimetric)
양식
solid
효능
>4640 mg/kg LD50, skin (Rabbit)
기술
UV/Vis spectroscopy: suitable
손실
≤0.2% loss on drying, 110 °C
≤0.2% loss on drying, 130 °C
pH
4.2-4.6 (20 °C, 20 g/L in H2O)
mp
252.6 °C (lit.)
solubility
208 g/L
density
2.338 g/mL at 25 °C (lit.)
벌크 밀도
1200 kg/m3
음이온 미량물
chloride (Cl-): ≤0.0005%
sulfate (SO42-): ≤0.003%
양이온 미량물
As: ≤0.0002%
Cu: ≤0.0003%
Fe: ≤0.0010%
N: ≤0.001%
Na: ≤0.02%
Pb: ≤0.001%
heavy metals (as Pb): ≤0.0010%
저장 온도
2-30°C
SMILES string
[K+].OP(O)([O-])=O
InChI
1S/K.H3O4P/c;1-5(2,3)4/h;(H3,1,2,3,4)/q+1;/p-1
InChI key
GNSKLFRGEWLPPA-UHFFFAOYSA-M
유사한 제품을 찾으십니까? 방문 제품 비교 안내
애플리케이션
- β-lactoglobulin stabilized nanemulsions--Formulation and process factors affecting droplet size and nanoemulsion stability.: This research explores the stabilization mechanisms of β-lactoglobulin in nanemulsions, with implications for pharmaceutical and food sciences, potentially utilizing substances like potassium phosphate monobasic for stability and pH control (Ali et al., 2016).
- Reverse phase liquid chromatographic determination of sulfathiazole residues in honey.: Discusses a method for detecting sulfathiazole in honey using reverse-phase liquid chromatography, highlighting the importance of analytical techniques that could involve reagents like potassium phosphate monobasic for sample preparation and analysis (Barry and MacEachern, 1983).
분석 메모
Assay (alkalimetric; dried substance): ≥ 99.5 %
pH-value (5 %; water): 4.2 - 4.5
Chloride (Cl): ≤ 0.0005 %
Sulfate (SO₄): ≤ 0.003 %
Total nitrogen (N): ≤ 0.001 %
Heavy metals (as Pb): ≤ 0.0010 %
As (Arsenic): ≤ 0.0002 %
Cu (Copper): ≤ 0.0003 %
Fe (Iron): ≤ 0.0010 %
Na (Sodium): ≤ 0.02 %
Pb (Lead): ≤ 0.001 %
Reducing substances: passes test
Loss on drying (110 °C): ≤ 0.2 %
Loss on drying (130 °C): ≤ 0.2 %
Correspons to ISO
법적 정보
Storage Class Code
13 - Non Combustible Solids
WGK
WGK 1
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
이미 열람한 고객
문서
Apixaban is sold under the tradename Eliquis and at present no pharmacopeial monographs are available for Axpixaban using either an assay and/or organic impurity profiling method. A newly developed and validated HPLC-UV method using a column with C18 solid core particles is demonstrated.
Following the new USP monograph for Famciclovir Tablets, Purospher™ STAR RP-8 endcapped HPLC columns can be used to monitor organic impurities in Famciclovir tablet formulations. Famciclovir is an antiviral drug indicated for the treatment of herpes zoster, herpes simplex virus 2 (genital herpes), herpes labialis (cold sores), etc.
프로토콜
This paper illustrates the setting up of a Lopinavir assay following European pharmacopoeia guidelines (10.2), and using a shorter column packed with smaller particles. The described assay saves valuable time and improves separation efficiency, which typically translates to better method performance.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.