추천 제품
vapor density
7 (vs air)
Quality Level
vapor pressure
~10 mmHg ( 25 °C)
분석
98%
양식
liquid
refractive index
n20/D 1.3 (lit.)
bp
120 °C/755 mmHg (lit.)
density
1.645 g/mL at 25 °C (lit.)
작용기
carboxylic acid
fluoro
SMILES string
OC(=O)C(F)(F)C(F)(F)C(F)(F)F
InChI
1S/C4HF7O2/c5-2(6,1(12)13)3(7,8)4(9,10)11/h(H,12,13)
InChI key
YPJUNDFVDDCYIH-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
Perfluorobutyric acid is an effective additive for zinc electrodeposition.
애플리케이션
Perfluorobutyric acid was used as mobile phase modifier for enhancement of selectivity in the HPLC analysis of histone proteins. It was used as ion pairing reagent in preparative and analytical reserved phase HPLC of underivatised peptides.
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Eye Dam. 1 - Skin Corr. 1A
Storage Class Code
8A - Combustible corrosive hazardous materials
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter
가장 최신 버전 중 하나를 선택하세요:
시험 성적서(COA)
Lot/Batch Number
이미 열람한 고객
D R Harding et al.
International journal of peptide and protein research, 18(2), 214-220 (1981-08-01)
This report describes the successful use of the ether soluble, ion pairing reagents perfluoropropoinic and perfluorobutyric acid in the preparative and analytical reserved phase HPLC of underivatised peptides. The preparative separation of a 1-g sample of Pyr-His-Gly, the proposed anorexigenic
M Naldi et al.
Journal of chromatography. A, 1129(1), 73-81 (2006-08-05)
The application of reversed-phase high-pressure liquid chromatography under gradient conditions and electrospray ion trap mass spectrometry (LC-ESI-MS) to the analysis of global modification levels of core histones is described. The optimised LC-ESI-MS method was applied for the first time to
Zinc electrowinning from acidic sulphate solutions Part IV: effects of perfluorocarboxylic acids.
Tripathy BC, et al.
Journal of Electroanalytical Chemistry, 565(1), 49-56 (2004)
Huilun Chen et al.
International journal of environmental research and public health, 17(4) (2020-02-23)
Perfluoroalkyl carboxylic acids (PFCAs) are some of the most significant pollutants in human serum, and are reported to be potentially toxic to humans. In this study, the binding mechanism of PFCAs with different carbon lengths to human serum albumin (HSA)
Yuko Murakami et al.
Organic & biomolecular chemistry, 12(48), 9887-9894 (2014-10-31)
Desmosine-CH2, an analog of the elastic tissue degradation biomarker desmosine, can be regarded as a potential internal standard for precise quantification of desmosines by LC-MS/MS. In this study, the chemical synthesis of desmosine-CH2 was completed in 22% overall yield in
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..