Přejít k obsahu
Merck

FSUPMMRO

Roche

FastStart Universal Probe Master (Rox)

sufficient for 250 reactions, sufficient for 1250 reactions, sufficient for 5000 reactions, suitable for qPCR, suitable for RT-qPCR

Přihlásitk zobrazení cen stanovených pro organizaci a smluvních cen

About This Item

UNSPSC Code:
41106300
NACRES:
NA.55
Technický servis
Potřebujete pomoc? Náš tým zkušených odborníků je vám k dispozici.
Dovolte nám, abychom vám pomohli
Technický servis
Potřebujete pomoc? Náš tým zkušených odborníků je vám k dispozici.
Dovolte nám, abychom vám pomohli

usage

sufficient for 1250 reactions
sufficient for 250 reactions
sufficient for 5000 reactions

Quality Level

feature

dNTPs included: no
hotstart

manufacturer/tradename

Roche

packaging

pkg of 1250 x 20 μL reactions (04913957001)
pkg of 250 x 20 μL reactions (04913949001)
pkg of 5000 x 20 μL reactions (04914058001)

technique(s)

RT-qPCR: suitable
qPCR: suitable

input

purified DNA

detection method

probe-based

General description

Hot start protocols have been shown to significantly improve the specificity, sensitivity, and yield of PCR. Heat-labile blocking groups on some of the amino acid residues of FastStart Taq DNA Polymerase make the modified enzyme inactive at room temperature. Therefore, there is no elongation during the period when primers can nonspecifically bind. FastStart Taq DNA Polymerase is activated by removing the blocking groups at a high temperature (i.e., a preincubation step at +95°C).
Universal ready-to-use hot start reaction mix for qPCR and RT-qPCR on all real-time PCR systems requiring normalization with ROX.

FastStart Universal Probe Master (Rox) includes a novel reference dye that enables its use on all real-time PCR instruments requiring normalization with ROX, without modification or adjustments to the specific instrument or protocol. This ready-to-use, 2x concentrated master mix contains all reagents (except primers, probe, and template) needed for running quantitative, real-time DNA-detection assays, including qPCR and two-step qRT-PCR, in the hydrolysis probe detection format. FastStart Universal Probe Master (Rox) generates excellent results on instruments such as the Applied Biosystems 7900 HT Fast Real-Time PCR System or the Applied Biosystems 7500 Real-Time PCR System. This product is not intended for use with the LightCycler® Instruments.

Application

FastStart Universal Probe Master (Rox) has been used:
  • in TaqMan® quantitative real-time polymerase chain reaction (qRT-PCR) reactions for the quantification of endogenous miRNAs, such as MIR376B, MIR376A and MIR181A
  • in reverse transcriptase (RT-PCR) to study tumor necrosis factor (TNF) expression in whole synovial tissue of undifferentiated peripheral inflammatory arthritis (UPIA) patients
  • for the amplification and detection of any DNA or cDNA target, including those that are GC- or AT-rich by quantitativePCR
Combine this master mix with Transcriptor First Strand cDNA Synthesis Kit (Roche) to achieve excellent results in two-step qRT-PCR.

Features and Benefits

  • Increase qPCR sensitivity and specificity.
Produce lower cycle threshold (Ct) values.

  • Use the master mix with any probe-based assay.
Achieve sensitive, specific results in assays with the Universal ProbeLibrary Probes or any other hydrolysis probe.

  • Amplify and detect a broad range of DNA or cDNA targets.
Amplify fragments up to 500 bp long, including those that are GC- or AT-rich.

  • Visualize amplification products on agarose gels.

  • Use robotic pipetting stations to set up qPCR reactions.
Use a master mix that is stable at room temperature during extended reaction setup times.

  • Prevent false positives resulting from carryover contamination.
Use this dUTP-containing mix with Uracil-DNA Glycosylase to eliminate contaminating DNA carried over from previous PCR reactions.

Components

FastStart Universal Probe Master (Rox), 2x concentrated master mix that contains FastStart Taq DNA Polymerase, Reaction Buffer, Nucleotides (dATP, dCTP, dGTP, dUTP), and a reference dye.

Quality

Function test: Each lot is tested for performance in qPCR using three templates: a GC–rich template, an AT-rich template, and a long template (approximately 440 bp).

Other Notes

For life science research only. Not for use in diagnostic procedures

Legal Information

FastStart is a trademark of Roche
LightCycler is a registered trademark of Roche
TaqMan is a registered trademark of Roche Molecular Systems, Inc.

Skladovací třída

12 - Non Combustible Liquids

wgk_germany

WGK 1

flash_point_f

does not flash

flash_point_c

does not flash


Vyberte jednu z posledních verzí:

Osvědčení o analýze (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Dokumenty section.

Potřebujete-li pomoc, obraťte se na Zákaznická podpora

Již tento produkt vlastníte?

Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.

Navštívit knihovnu dokumentů

Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..

Obraťte se na technický servis