FSUPMMRO
Roche
FastStart Universal Probe Master (Rox)
sufficient for 250 reactions, sufficient for 1250 reactions, sufficient for 5000 reactions, suitable for qPCR, suitable for RT-qPCR
About This Item
usage
sufficient for 1250 reactions
sufficient for 250 reactions
sufficient for 5000 reactions
Quality Level
feature
dNTPs included: no
hotstart
manufacturer/tradename
Roche
packaging
pkg of 1250 x 20 μL reactions (04913957001)
pkg of 250 x 20 μL reactions (04913949001)
pkg of 5000 x 20 μL reactions (04914058001)
technique(s)
RT-qPCR: suitable
qPCR: suitable
input
purified DNA
detection method
probe-based
Související kategorie
General description
FastStart™ Universal Probe Master (Rox) includes a novel reference dye that enables its use on all real-time PCR instruments requiring normalization with ROX, without modification or adjustments to the specific instrument or protocol. This ready-to-use, 2x concentrated master mix contains all reagents (except primers, probe, and template) needed for running quantitative, real-time DNA-detection assays, including qPCR and two-step qRT-PCR, in the hydrolysis probe detection format. FastStart™ Universal Probe Master (Rox) generates excellent results on instruments such as the Applied Biosystems 7900 HT Fast Real-Time PCR System or the Applied Biosystems 7500 Real-Time PCR System. This product is not intended for use with the LightCycler® Instruments.
Application
- in TaqMan® quantitative real-time polymerase chain reaction (qRT-PCR) reactions for the quantification of endogenous miRNAs, such as MIR376B, MIR376A and MIR181A
- in reverse transcriptase (RT-PCR) to study tumor necrosis factor (TNF) expression in whole synovial tissue of undifferentiated peripheral inflammatory arthritis (UPIA) patients
- for the amplification and detection of any DNA or cDNA target, including those that are GC- or AT-rich by quantitativePCR
Features and Benefits
- Increase qPCR sensitivity and specificity.
- Use the master mix with any probe-based assay.
- Amplify and detect a broad range of DNA or cDNA targets.
- Visualize amplification products on agarose gels.
- Use robotic pipetting stations to set up qPCR reactions.
- Prevent false positives resulting from carryover contamination.
Components
Quality
Other Notes
Legal Information
Skladovací třída
12 - Non Combustible Liquids
wgk_germany
WGK 1
flash_point_f
does not flash
flash_point_c
does not flash
Vyberte jednu z posledních verzí:
Osvědčení o analýze (COA)
It looks like we've run into a problem, but you can still download Certificates of Analysis from our Dokumenty section.
Potřebujete-li pomoc, obraťte se na Zákaznická podpora
Již tento produkt vlastníte?
Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.
Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..
Obraťte se na technický servis