Skip to Content
MilliporeSigma
  • Evaluation of an electrochemical biosensor for uric acid measurement in human whole blood samples.

Evaluation of an electrochemical biosensor for uric acid measurement in human whole blood samples.

Clinica chimica acta; international journal of clinical chemistry (2014-05-13)
Li-Ting Liao, Chi-Chih Liao, Chiu-Ching Liu, Ting-Ya Yang, Giueng-Chueng Wang
ABSTRACT

Uric acid measurement has become increasingly important, and electrochemically modified detection method based portable devices hold a dominant position in the market for point of care and self-monitoring of uric acid blood levels. However, there has been a lack of detailed performance evaluation of the electrochemical detection devices that are currently being used in professional health care facilities and for home self-monitoring of uric acid. A commercially available uric acid monitoring system that is chemically modified to reduce interference was evaluated via clinical evaluation for its performance and interference as compared to a centralized laboratory instrument. Precision was within ±3.1% for 3 levels of control solutions and whole blood samples. A range from 30 to 55% was acceptable for the measurement of hematocrit levels in whole blood samples. There was no interference for the potential substances at their high therapeutic levels. Hemolyzed samples of up to 75 g/l showed no interference with test results obtained by the BeneCheck system, while a -45.9% bias% was obtained during testing of the same samples by a spectrophotometer. Clinical evaluation showed that >95% of tests were within ±20% bias% compared to a centralized instrument in hospitals. The uric acid monitoring system was suitable for use in monitoring or screening uric acid concentration for home users or professionals.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Sodium chloride, BioPerformance Certified, ≥99% (titration), suitable for insect cell culture, suitable for plant cell culture
SAFC
Sodium chloride solution, 5 M
Supelco
Indomethacin, Pharmaceutical Secondary Standard; Certified Reference Material
Ibuprofen, European Pharmacopoeia (EP) Reference Standard
Indomethacin, European Pharmacopoeia (EP) Reference Standard
Atenolol, European Pharmacopoeia (EP) Reference Standard
USP
Atenolol, United States Pharmacopeia (USP) Reference Standard
USP
Indomethacin, United States Pharmacopeia (USP) Reference Standard
SAFC
Cholesterol, from sheep wool, Controlled origin, meets USP/NF testing specifications
Ibuprofen for peak identification, European Pharmacopoeia (EP) Reference Standard
Didanosine impurity A,, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
Cholesterol, powder, BioReagent, suitable for cell culture, ≥99%
Sigma-Aldrich
Cholesterol, Sigma Grade, ≥99%
Sigma-Aldrich
Cholesterol, from sheep wool, ≥92.5% (GC), powder
Sigma-Aldrich
Sodium L-lactate, ~98%
Sigma-Aldrich
Hypoxanthine, ≥99.0%
Sigma-Aldrich
Indomethacin, 98.5-100.5% (in accordance with EP)
Sigma-Aldrich
Hypoxanthine, powder, BioReagent, suitable for cell culture
Sigma-Aldrich
L-Ascorbic acid, suitable for cell culture, suitable for plant cell culture, ≥98%
Sigma-Aldrich
L-Ascorbic acid, reagent grade
Sigma-Aldrich
L-Ascorbic acid, meets USP testing specifications
Sigma-Aldrich
Indomethacin, meets USP testing specifications
Sigma-Aldrich
Sodium chloride solution, 5 M
Sigma-Aldrich
Sodium chloride solution, 5 M in H2O, BioReagent, suitable for cell culture
Sigma-Aldrich
Atenolol, ≥98% (TLC), powder
Sigma-Aldrich
Ibuprofen, meets USP testing specifications
Sigma-Aldrich
Ibuprofen, ≥98% (GC)
Sigma-Aldrich
Tetracycline, 98.0-102.0% (HPLC)
Sigma-Aldrich
Sodium chloride, meets analytical specification of Ph. Eur., BP, USP, 99.0-100.5%
Sigma-Aldrich
Sodium chloride solution, 0.9% in water, BioXtra, suitable for cell culture