์ฝ˜ํ…์ธ ๋กœ ๊ฑด๋„ˆ๋›ฐ๊ธฐ
Merck
  • Affinity Capillary Electrophoresis for Selective Control of Electrophoretic Mobility of Sialic Acid Using Lanthanide-Hexadentate Macrocyclic Polyazacarboxylate Complexes.

Affinity Capillary Electrophoresis for Selective Control of Electrophoretic Mobility of Sialic Acid Using Lanthanide-Hexadentate Macrocyclic Polyazacarboxylate Complexes.

Analytical sciences : the international journal of the Japan Society for Analytical Chemistry (2015-11-13)
Daiki Goto, Kazuki Ouchi, Masami Shibukawa, Shingo Saito
์ดˆ๋ก

It is difficult to control the electrophoretic mobility in order to obtain high resolution among saccharides in complex samples. We report herein on a new affinity capillary electrophoresis (ACE) method for an anionic monosaccharide, N-acetylneuraminic acid (Neu5Ac), which is important in terms of pathological diagnosis, using lanthanide-hexadentate macrocyclic polyazacarboxylate complexes (Ln-NOTA) as affinity reagents. It was shown that Ln-NOTA complexes increased the anionic mobility of Neu5Ac by approximately 40% through selective complexation with Neu5Ac. The extent of change in the mobility strongly depended on the type of central metal ion of Ln-NOTA. The stability constant (K) of Lu-NOTA with Neu5Ac was determined by ACE to be log Kb = 3.62 ยฑ 0.04, which is the highest value among artificial receptors for Neu5Ac reported so far. Using this ACE, the Neu5Ac content in a glycoprotein sample, ฮฑ1-acid glycoprotein (AGP), was determined after acid hydrolysis. Complete separation between Neu5Ac and hydrolysis products was successful by controlling the mobility to determine the concentration of Neu5Ac.

MATERIALS
์ œํ’ˆ ๋ฒˆํ˜ธ
๋ธŒ๋žœ๋“œ
์ œํ’ˆ ์„ค๋ช…

Ytterbium, rod, 50mm, diameter 2.0mm, cast, 99%
Ytterbium, foil, not light tested, 25x25mm, thickness 0.005mm, as rolled, 99%
Ytterbium, rod, 50mm, diameter 6.35mm, cast, 99%
Ytterbium, foil, not light tested, 25x25mm, thickness 0.025mm, as rolled, 99%
Ytterbium, foil, not light tested, 50x50mm, thickness 0.025mm, as rolled, 99%
Ytterbium, lump, 50g, max. size 25mm, 99.9%
Ytterbium, rod, 100mm, diameter 10.0mm, cast, 99%
Ytterbium, rod, 100mm, diameter 6.35mm, cast, 99%
Ytterbium, rod, 50mm, diameter 10.0mm, cast, 99%
Ytterbium, lump, 100g, max. size 25mm, 99.9%
Ytterbium, lump, 25g, max. size 25mm, 99.9%
Terbium, foil, not light tested, 50x50mm, thickness 0.025mm, as rolled, 99%
Terbium, powder, 2g, max. particle size 500 micron, 99.9%
Terbium, foil, 50x50mm, thickness 0.1mm, as rolled, 99%
Terbium, powder, 5g, max. particle size 500 micron, 99.9%
Terbium, foil, not light tested, 25x25mm, thickness 0.025mm, as rolled, 99%
Terbium, rod, 100mm, diameter 6.35mm, cast, 99%
Terbium, rod, 50mm, diameter 6.35mm, cast, 99%
Terbium, foil, 25x25mm, thickness 0.1mm, as rolled, 99%
Sigma-Aldrich
DL-Histidine, โ‰ฅ99% (TLC)
Sigma-Aldrich
D-(โˆ’)-Ribose, โ‰ฅ99% (GC)
SAFC
Glycine
Sigma-Aldrich
Ytterbium, powder, ≥99.9% trace rare earth metals basis
Sigma-Aldrich
D-(โˆ’)-Ribose, โ‰ฅ98%
Sigma-Aldrich
DL-Tryptophan, โ‰ฅ99% (HPLC)
Sigma-Aldrich
D-(โˆ’)-Ribose, 98%
Sigma-Aldrich
Glycine, BioUltra, ≥99.0% (NT)
Sigma-Aldrich
Glycine, 99%, FCC
Sigma-Aldrich
Glycine, puriss. p.a., reag. Ph. Eur., buffer substance, 99.7-101% (calc. to the dried substance)
Sigma-Aldrich
Glycine, suitable for electrophoresis, ≥99%