콘텐츠로 건너뛰기
Merck
  • Simultaneous derivatization and solid-based disperser liquid-liquid microextraction for extraction and preconcentration of some antidepressants and an antiarrhythmic agent in urine and plasma samples followed by GC-FID.

Simultaneous derivatization and solid-based disperser liquid-liquid microextraction for extraction and preconcentration of some antidepressants and an antiarrhythmic agent in urine and plasma samples followed by GC-FID.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2015-01-27)
Mir Ali Farajzadeh, Parisa Khorram, Houshang Ghorbanpour
초록

The present work is based on a one-step method including derivatization and solid-based disperser liquid-liquid microextraction followed by gas chromatography-flame ionization detection (GC-FID) for the determination of four antidepressants (fluoxetine, fluvoxamine, tranylcypromine, and nortriptyline) and an antiarrhythmic agent (mexiletine) in human urine and plasma samples. In this method, a mixture of 1,1,2,2-tetrachloroethane (extraction solvent) and butylchloroformate (derivatizing reagent) is added on a sugar cube (solid disperser) and it is introduced into an aqueous sample containing the analytes and a catalyst, e.g. 3-methylpyridine (picoline). During dissolving the sugar cube by manual shaking, the extractant and derivatization agent are gradually released into the sample as very fine droplets. Then the resulted cloudy solution is centrifuged and the sedimented phase is analyzed by GC-FID. The influence of several variables on the efficiency of derivatization/microextraction procedure such as kind and volume of extraction solvent, type and amount of disperser, amount of derivatization agent, and catalyst volume are optimized. Under the optimum conditions the calibration curves are linear in the range of 8-100,000μgL(-1) (coefficient of determination ≥0.994). The relative standard deviations are obtained in the range of 3.0-6.0% for all compounds. Moreover, the detection limits and enrichment factors of the target analytes are obtained in the ranges 1-15μgL(-1) and 228-268, respectively, for both plasma and urine samples. The relative recoveries obtained for the spiked plasma and urine samples are between 70 and 91%. The results show that the proposed method is simple, reliable, low cost, and applicable to determine trace amounts of the studied drugs in biological samples.

MATERIALS
제품 번호
브랜드
제품 설명

SAFC
Sodium chloride solution, 5 M
Supelco
Hydrogen chloride – ethanol solution, ~1.25 M HCl, LiChropur
Supelco
1,1,2,2-Tetrachloroethane, analytical standard
Sigma-Aldrich
Chloroform, anhydrous, ≥99%, contains 0.5-1.0% ethanol as stabilizer
Sigma-Aldrich
Sodium chloride-35Cl, 99 atom % 35Cl
Supelco
Chloroform, suitable for HPLC, ≥99.8%, contains 0.5-1.0% ethanol as stabilizer
Sigma-Aldrich
Chloroform, ACS reagent, ≥99.8%, contains amylenes as stabilizer
Sigma-Aldrich
Hydrochloric acid, meets analytical specification of Ph. Eur., BP, NF, fuming, 36.5-38%
Sigma-Aldrich
Hydrochloric acid, ACS reagent, 37%
Supelco
Hydrochloric acid solution, volumetric, 0.1 M HCl (0.1N), endotoxin free
Sigma-Aldrich
Hydrochloric acid, ACS reagent, 37%
Sigma-Aldrich
Hydrochloric acid, BioReagent, 36.5-38.0%
Sigma-Aldrich
Sodium chloride, random crystals, optical grade, 99.9% trace metals basis
Sigma-Aldrich
Sodium hydroxide solution, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
Sodium hydroxide, beads, 16-60 mesh, reagent grade, 97%
Sigma-Aldrich
Sodium hydroxide, anhydrous, free-flowing, Redi-Dri, reagent grade, ≥98%, pellets
Sigma-Aldrich
Sodium hydroxide, reagent grade, 97%, powder
Sigma-Aldrich
Sodium hydroxide solution, BioUltra, 10 M in H2O
Sigma-Aldrich
Sodium hydroxide, puriss. p.a., ACS reagent, reag. Ph. Eur., K ≤0.02%, ≥98%, pellets
Sigma-Aldrich
Sodium chloride, AnhydroBeads, −10 mesh, 99.999% trace metals basis
Sigma-Aldrich
Sodium chloride, BioUltra, ≥99.5% (AT)
Sigma-Aldrich
Chloroform, contains ethanol as stabilizer, meets analytical specification of BP, 99-99.4% (GC)
Sigma-Aldrich
3-Ethyl-2,4-pentanedione, mixture of tautomers, 98%
Supelco
Hydrogen chloride – methanol solution, ~1.25 m HCl (T), derivatization grade (GC derivatization), LiChropur
Sigma-Aldrich
Hydrogen chloride solution, 3 M in cyclopentyl methyl ether (CPME)
Sigma-Aldrich
Hydrochloric acid, puriss., 24.5-26.0%
Sigma-Aldrich
Hydrogen chloride solution, 1.0 M in acetic acid
Sigma-Aldrich
Hydrogen chloride solution, 1.0 M in diethyl ether
Sigma-Aldrich
Hydrogen chloride solution, 2.0 M in diethyl ether
Sigma-Aldrich
Hydrochloric acid, 37 wt. % in H2O, 99.999% trace metals basis