콘텐츠로 건너뛰기
Merck
  • Mass spectrometric behavior of phenolic acids standards and their analysis in the plant samples with LC/ESI/MS system.

Mass spectrometric behavior of phenolic acids standards and their analysis in the plant samples with LC/ESI/MS system.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-07-27)
Wojciech Ostrowski, Anna Wojakowska, Magdalena Grajzer, Maciej Stobiecki
초록

Liquid chromatography coupled to mass spectrometry (MS) with electrospray ionization (ESI) is one of analytical techniques to obtain accurate results of low molecular weight aromatic compounds in biological samples of different origin. The interpretations of mass spectra of these aromatic compounds in the negative spectra registered in the full scan MS mode may be uneasy due to presence of deprotonated molecules [M-H](-) from different co-eluting entities, fragment ions created after the break-up of precursor ions and also ions representing modified molecules clusters. Thus, the first aim of this study was to evaluate general parameters during analysis performed in the full scan MS or MS/MS mode. Secondly, to set general fragmentation rules for aromatic compounds and entities in a complex biological matrix. We established that different groups of low molecular weight phenolic acids form unique adduct ions and additionally registration LC/MS/MS spectra with two different collision energies may allow for differentiating isomeric or isobaric molecules. These findings together with some general fragmentation rules can facilitate identifications of aromatic acids as we outlined in the sample of cold-pressed rose-hip oil and lupine leaves extract.

MATERIALS
제품 번호
브랜드
제품 설명

Supelco
Melting point standard 182-184°C, analytical standard
Supelco
3,4-Dihydroxyphenylacetic acid, analytical standard
Supelco
Vanillin melting point standard, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Sinapic acid, ≥99.5%, Ultra pure
Supelco
Salicylic acid, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Salicylic acid, meets analytical specification of Ph. Eur., BP, USP, 99.5-100.5% (calc. to the dried substance)
Supelco
Salicylic acid, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Vanillin, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
3-Hydroxybenzaldehyde, ≥99%
Sigma-Aldrich
3-Methoxybenzoic acid, ReagentPlus®, 99%
Supelco
4-Hydroxybenzaldehyde, analytical standard
Sigma-Aldrich
Acetovanillone, ≥98%, FG
Salicylic acid, European Pharmacopoeia (EP) Reference Standard
Supelco
Salicylic acid, 1.0 mg/mL in acetonitrile, ampule of 1 mL, certified reference material, Cerilliant®
Sigma-Aldrich
2-Hydroxyphenylacetic acid, ReagentPlus®, 99%
Sigma-Aldrich
p-Anisic acid, ≥99%, FG
Sigma-Aldrich
4′-Hydroxy-3′-methoxyacetophenone, 98%
Sigma-Aldrich
4-Hydroxybenzaldehyde, ≥95.0% (HPLC)
Sigma-Aldrich
3-Hydroxyphenylacetic acid, ≥99%
Sigma-Aldrich
3,5-Dihydroxybenzoic acid, 97%
Sigma-Aldrich
2-Benzoylbenzoic acid, 98%
Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Sigma-Aldrich
Acetonitrile solution, contains 0.05 % (v/v) trifluoroacetic acid
Sigma-Aldrich
4-Hydroxybenzaldehyde, ≥97%, FG
Sigma-Aldrich
Salicylic acid, ≥99%, FG
Sigma-Aldrich
Vanillic acid, ≥97%, FG
Supelco
Mettler-Toledo Calibration substance ME 51143093, Vanillin, traceable to primary standards (LGC)
Supelco
Sinapic acid, ≥99.0% (T)
Sigma-Aldrich
Sinapic acid, ≥98%, powder